Hampton Solubility & Stability Screen

Hampton Solubility & Stability Screen

Solubility & Stability Screen(溶解度和稳定性的屏幕)

应用:溶解性和稳定性屏幕的设计,以协助识别解决方案的条件,促进蛋白质的溶解性和稳定性,并尽量减少蛋白质沉淀。

Solubility & Stability Screen

Solubility & Stability Screen

Solubility & Stability Screen

Solubility & Stability Screen HR2-072

Applications

A solubility screen, a stability screen, an additive screen for protein assays including ThermoFluor and crystallization
Preformulation screening

 

Compatible with Thermofluor , Differential Scanning Fluorimetry (DSF), and Protein Thermal Shift assays
96 sterile filtered reagents
17 classes of reagents and excipients
Highly concentrated (10x) reagent formulation
Developed at Hampton Research

Features

Methodologies

Thermal shift assay
Dynamic Light Scattering
Use Solubility & Stability Screen along side Slice pH and Solubility & Stability Screen 2 to optimize sample buffer
Description

Solubility & Stability Screen is designed to assist in the identification of solution conditions which promote protein solubility and stability, and minimize protein precipitation. Solubility & Stability Screen is a solubility screen, a stability screen, and may also be used as an additive screen in the presence of a crystallization reagent.

The Hampton Research Solubility and Stability Screen can evaluate protein solubility, stability and crystallization in the presence of 94 different chemical additives sampling 17 different classes of reagents plus two controls.

Protein solubility and stability are universally required in a wide range of applications, including general biochemical studies, the preparation of proteins in pharmaceuticals, structural biology and crystallization.1-11The preparation of a concentrated, soluble and stable protein sample can often be a difficult task as proteins often aggregate, precipitate or denature.

Thermofluor (also known as Differential Scanning Fluorimetry, DSF and Protein Thermal Shift) provides a rapid, convenient and effective means of identifying subsaturating solution conditions that may also correlate with protein heterogeneity and poor crystallization outcomes.12

Protein solubility and stability is affected by many different chemical factors including pH, buffer type, chemical additives and excipients. pH and buffer type are dominant protein solubility and stability variables and can be evaluated and optimized using the Hampton Research Slice pH kit HR2-070. Slice pH evaluates protein solubility, stability and crystallization versus 20 different buffers over the pH range 3.5-9.6. Chemical additives influencing protein solubility and stability can be evaluated using the Solubility & Stability Screen.

It is widely accepted that protein solubility and stability can be increased by the use of chemical additives.5,15Seventeen classes of reagents are sampled by the Solubility & Stability Screen and each of these classes has been reported as important in improving sample solubility and stability.2-11

The Solubility & Stability Screen is a set of 94 high purity reagents formulated in high purity water (NCCLS/ASTM Type 1+) at 25°C and are 0.22 micron sterile filtered. The 94 solubility and stability reagents are formulated at 2 to 10 times their recommended working concentration. The remaining two reagents are water and a negative (TCA) control. A water control demonstrates the effect of diluting sample as well as sample buffer concentration. TCA, the negative control, demonstrates total sample precipitation, loss of sample solubility and loss of sample stability. The effects of the Solubility & Stability reagents can be compared with this negative control to assist in the identification of reagents promoting sample solubility and stability. 500 microliters of each reagent is supplied in a sterile 96 well polypropylene Deep Well block. The Solubility & Stability Screen reagents are compatible with the sitting or hanging drop vapor diffusion, microbatch, free interface diffusion, sandwich drop vapor diffusion, and dialysis crystallization methods utilizing water soluble reagents.

Hampton 24孔坐滴板 Cryschem Plate

Hampton 24孔坐滴板 Cryschem Plate

Applications

 Sitting drop crystallization

  Heavy atom soaks

  Seeding

Features

Optically clear, concave sitting drop post
Cryschem Plate – Larger footprint and round reagent reservoir
Cryschem M – Microplate footprint with round reagent reservoir
Cryschem S – Microplate footprint with square reagent reservoir

Compatible with Formulatrix Formulator

Smooth, flat top for easy seal
Each plate supplied with a cover

Materials

  Optically clear polystyrene

 Description

The Cryschem Plate is a 24 well sitting drop plate that is sealed with clear sealing tape. The polystyrene plate is supplied with a raised cover so the plate can also be sealed with vacuum grease and plain glass or plastic cover slides (22 mm diameter). The stackable, 24 well plates have distortion-free, flat bottom wells and a concave sitting drop post in the center of the well for concentric equilibration of the drop with the reagent. Each plate is individually sealed. The top of the plate and each of the 24 wells is a single, flat plane for smooth and easy seal application. Well spacing provides for a large seal area between wells to prevent cross contamination and evaporation.

上海金畔生物作为Hampton蛋白结晶产品的代理商,竭诚为您服务,欢迎新老客户咨询。

Cryschem Plate is large plate footprint with circular reagent reservoir. Cryschem plate approximate size: 15.1 cm x 10.6 cm x 2.2 cm. Approximate well size: 1.6 cm x 1.5 cm. Typical fill volume: 500 to 1,000 µl. Well capacity: 1.5 ml. Maximum drop volume on post: 40 µl. Recommended seal: HR3-511 Crystal Clear Sealing Tape (1.88 inch x 43.7 yard roll, with cutter) or HR4-511 Crystal Clear Sealing Tape (1.88 inch x 60 yard roll, without cutter).

Cryschem M Plate is microplate footprint with circular reagent reservoir. Cryschem M microplate approximate size: 128 mm x 86 mm x 14 mm. Approximate circular reservoir size: 15 mm wide x 9 mm deep. Typical reservoir volume: 500 µl. Well capacity: 1.1 ml. Maximum drop volume on post: 30 µl. Recommended seal: HR3-609 Crystal Clear Sealing Film (100 pack), HR4-521 ClearSeal Film (100 pack) or HR4-506 Crystal Clear Sealing Tape (3 inch x 55 yard roll, without cutter). HR4-508 Crystal Clear Sealing Tape (0.75 inch x 650 inch, with cutter) seals a single row at a time.

Cryschem S Plate is microplate footprint with square reagent reservoir. Cryschem S microplate approximate size: 128 mm x 86 mm x 14 mm. Approximate square reservoir size: 15 mm wide x 9 mm deep. Typical reservoir volume: 500 µl. Well capacity: 1.1 ml. Maximum drop volume on post: 30 µl. Recommended seal: HR3-609 Crystal Clear Sealing Film (100 pack), HR4-521 ClearSeal Film (100 pack) or HR4-506 Crystal Clear Sealing Tape (3 inch x 55 yard roll, without cutter). HR4-508 Crystal Clear Sealing Tape (0.75 inch x 650 inch, with cutter) seals a single row at a time.

Cryschem Plate

Cryschem plate

CAT NO NAME DESCRIPTION
HR3-158 Cryschem Plate 24 plate case
HR3-160 Cryschem Plate 100 plate case
HR1-002 Cryschem M Plate (round reagent reservoir) 50 plate case
HR3-308 Cryschem S Plate (square reagent reservoir) 50 plate case

Sigma代理  Abcam代理  CST代理  Santa Cruz代理  Biolegend代理 ebioscience代理  Invitrogen代理   millipore代理  BD流式抗体代理   GeneTe x抗体代理  Novus抗体代理   R&D代理 Biovison代理  Jackson代理  MBL抗体代理  ProSpec抗体代理  Bethyl抗体代理  Antibody Revolution抗体代理  Torrey Pines Biolabs代理  Amresco代理  MPbio代理  Laysan bio代理  NANOCS代理  Avanti代理  wako代理  lumiprobe代理(活性荧光染料)   NEB酶代理  Roche酶代理  Toyobo酶代理   USP代理  EP代理  Dr代理  TRC代理  TCI代理  Reagecon代理 Megazyme代理 Hampton代理(蛋白结晶) whatman代理(滤膜滤纸) GE代理(蛋白纯化) Corning康宁代理  Axygen代理 Falcon代理  NISSUI日水代理 Himedia代理 OXOID代理  BD培养基代理 Ludger代理(糖蛋白分析产品)  Eppendorf代理  Labnet代理  标准品代理 抗体代理 酶试剂代理  培养基代理 耗材代理 Elisa试剂盒代理 。

Hampton Polyethylene glycol 4,000

Hampton Polyethylene glycol 4,000

Applications
Crystallization grade Polyethylene glycol for formulating screens or for optimizatio
Features
Sterile filtered solution
Formulated in Type 1+ ultrapure water: 18.2 megaohm-cm resistivity at 25°C, < 5 ppb Total Organic Carbon, bacteria free (<1 Bacteria (CFU/ml)), pyrogen free (<0.03 Endotoxin (EU/ml)), RNase-free (< 0.01 ng/mL) and DNase-free (< 4 pg/µL)

Description
Polyethylene glycol 4,000
Synonym: PEG 4,000
H(OCH2CH2)nOH
Mr 3,500-4,500
CAS Number [25322-68-3]
EC Number 500-038-2
Merck 14,7568
RTECS TQ3500000
MDL Number MFCD00081839
PubChem Substance ID 24890217
Melting point (Starting Material) 58.0-61.0°C
Aldehyde None detected
Peroxide None detected

HR2-529 Measured pH range: 6.9 – 9.5 at 25°C
HR2-529 Measured Conductivity Range: 35.3 – 46.9 µS/cm at 25°C
HR2-529 Measured Refractive Index Range: 1.40172 – 1.40279 at 20°C

CAT NO NAME DESCRIPTION
HR2-605 Polyethylene glycol 4,000 Flake – 500 g
HR2-529 Polyethylene glycol 4,000 50% w/v solution – 200 ml

Hampton Siliconized Glass Cover Slides

Hampton Siliconized Glass Cover Slides

ApplicationsHanging, sitting or sandwich drop crystallization
FeaturesHigh purity of glassSiliconized, hydrophobic glass surface0.22 mm & 0.96 mm glass thicknessThicker glass slides preserve temperature longer12 mm, 18 mm, & 22 mm glass diameterCircle & squareUV Compatible (>85% transmission)
12 x 0.22 mm Circle
18 x 0.22 mm Circle
22 x 0.22 mm Circle & Square

Description
Siliconized glass cover slides allow a droplet to be suspended in a position which provides near optimal conditions for vapor diffusion with the surrounding reservoir solution. These siliconized glass cover slides provide a consistent, high quality finish for crystallization experiments. The hydrophobic surface produces a drop which “stands well” and does not flatten on the glass. The siliconized surface prevents the adhesion of crystals and precipitate onto the glass surface. Use Dow Corning Vacuum Grease (HR3-510), Dow Corning 7 Release Compound (HR3-508), or immersion oil to seal cover slide to plate. Available in 12, 18 or 22 mm diameter circles and 22 mm diameter squares. Available in 0.22 mm or 0.96 mm glass thickness. The 0.96 mm thick slides are virtually unbreakable during crystallization handling.

The following slides are UV transmissable (>85%):
HR3-277 and HR3-279 – 12 mm x 0.22 mm Siliconized circle cover slides
HR3-231 and HR3-233 – 22 mm x 0.22 mm Siliconized circle cover slides
HR3-239 and HR3-241 – 18 mm x 0.22 mm Siliconized circle cover slides
HR3-215 and HR3-217 – 22 mm x 0.22 mm Siliconized square cover slides

图片

图片
Plain Glass Cover Slides
ApplicationsHanging, sitting or sandwich drop crystallization
Features
0.22 mm glass thickness
12 mm glass diameter
Hydrophilic glass surface
Circle & squareDescription
Plain, non-siliconized, hydrophilic glass cover slides. Useful for hanging drop, sitting drop, and sandwich drop vapor diffusion crystallization methods. The hydrophilic surface creates a drop which is more flat than a drop on a siliconized surface. This offers enhanced imaging for very small drops. Use Dow Corning® Vacuum Grease (HR3-510), Dow Corning® 7 Release Compound (HR3-508), or immersion oil to seal cover slide to plate.

HR3-209T 12 mm Plain circle cover slides for Tecan robot 5 oz case (~2,400 slides)

图片

图片
HR3-209T 12 mm Plain circle cover slides for Tecan robot 5 oz case (~2,400 slides)
PEN-VAC Kit
ApplicationsHolding and manipulating small, flat surfaces such as glass cover slides
FeaturesSelf-contained vacuumNo power neededCompactDescription
PEN-VAC is a great tool for handling small, flat surfaced objects such as plain and siliconized cover slides, as well as plastic slides. Simply depress the side button, touch the tip to the object to be lifted and release the button. PEN-VAC creates a totally self-contained vacuum that lifts up to 50 grams for up to one minute. Less than an ounce, the lightweight aluminum body fits in a pocket. No power supply needed. The kit includes one PEN-VAC with 5 3/4″ blue body, (3) angled and (3) straight probes with (2) each 1/8”, 1/4”, 3/8” diameter blue silicone vacuum cups . It is packaged in a clear plastic storage case.

图片
HR3-251  PEN-VAC Kit

Hampton 0.1毫米50号玻璃毛细管

Hampton 0.1毫米50号玻璃毛细管

货号:HR6-104
包装:25 pack

  • 英文名:0.1 mm Glass Number 50 Capillary
  • 品牌:Hampton
Hampton 0.1毫米50号玻璃毛细管

Hampton代理–金畔生物

硼硅玻璃50号毛细管壁厚0.01毫米,全长80毫米+ / – 5毫米。提供外径从0.1毫米到2毫米的毛细管,用于X射线数据收集,晶体密度测量和晶体生长实验。毛细管可以用蜡,环氧树脂等密封材料封闭,防止水分和气体。

应用

X射线数据采集

液-液扩散结晶

凝胶针状结晶

特征

50号硼硅玻璃

壁厚 10微米

描述

硼硅玻璃50号毛细管一端呈漏斗形,另一端封闭,壁厚0.01毫米,全长80毫米+/-5毫米,外径从0.1毫米到2毫米。可嵌入,盛放,储存小分子和生物大分子晶体用于X射线数据收集,晶体密度测量和晶体生长实验。毛细管可以用蜡,环氧树脂和其它密封材料密封,防止水分和气体。

请参照“线性吸收系数µcm-1表“,以决定适合的玻璃/石英玻璃毛细管。本表展示的是X射线数据收集时的辐射吸收量。

0.1mm至2.0mm毛细管开口端的基础尺寸为:3.0+/-0.15mm外径 x 0.13+/-0.10 mm壁厚,直径为在毛细管封闭端40毫米处的测量值。

 

货号

产品说明

公差

HR6-104

Size: 0.1 mm – 25 pack

0.1 mm -0.075 / +0.075 mm

HR6-106

Size: 0.2 mm – 25 pack

0.2 mm -0.050 / +0.050 mm

HR6-108

Size: 0.3 mm – 25 pack

0.3 mm -0.050 / +0.100 mm

HR6-110

Size: 0.4 mm – 25 pack

0.4 mm -0.100 / +0.100 mm

HR6-112

Size: 0.5 mm – 25 pack

0.5 mm -0.100 / +0.100 mm

HR6-114

Size: 0.6 mm – 25 pack

0.6 mm -0.100 / +0.100 mm

HR6-116

Size: 0.7 mm – 25 pack

0.7 mm -0.150 / +0.150 mm

HR6-118

Size: 0.8 mm – 25 pack

0.8 mm -0.150 / +0.150 mm

HR6-120

Size: 0.9 mm – 25 pack

0.9 mm -0.150 / +0.150 mm

HR6-122

Size: 1.0 mm – 25 pack

1.0 mm -0.150 / +0.250 mm

HR6-124

Size: 1.5 mm – 25 pack

1.5 mm -0.250 / +0.250 mm

HR6-126

Size: 2.0 mm – 25 pack

2.0 mm -0.250 / +0.250 mm

Hampton GRAS 5 • GRAS 6 Screens

Hampton GRAS 5 • GRAS 6 Screens

Applications

 GRAS reagent crystallization screen for proteins, including monoclonal antibodies, where Polyethylene glycol is the primary reagent, sampling pH 4.5 to 10

. Identify GRAS based reagents that promote crystallization of biotherapeutics for bioprocess, bioformulation, and continuous flow manufacturing applications

Features

Developed at Hampton Research
Generally Recognized As Safe reagent formulation
Samples pH 4.5 to 10; 8 unique buffers
Primary crystallization reagent:

GRAS 5: PEG 300, 400, MME 550, & 600
GRAS 6: PEG 1,000, MME 2,000, 3,350 & 4,000

 

Vapor diffusion, microbatch, free interface diffusion
Reagents soluble between 4°C and 30°C

Description

GRAS Screen™ 5 and 6 were developed by Hampton Research for the crystallization of proteins, including monoclonal antibodies. Each of the chemicals in GRAS Screen 5 and 6 has been used under one or more of the following categories. As (1) a Generally Recognized As Safe (GRAS) substance, (2) a pharmaceutical excipient, (3) a normal physiological constituent, (4) a metabolic byproduct, and/or (5) a Everything Added to Food in the United States (EAFUS) substance.

GRAS Screen 5 samples four low molecular weight Polyethylene glycols (300, 400, MME 550, and 600) at three concentrations versus eight unique buffers encompassing pH 4.5 to 10. GRAS Screen 5 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 5 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.

GRAS Screen 6 samples four medium molecular weight Polyethylene glycols (1,000, MME 2,000, 3,350, & 4,000) at three concentrations versus eight unique buffers encompassing pH 4.5 to 10. GRAS Screen 6 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 6 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.

Hampton 蛋白结晶试剂–Crystal Screen

Hampton 蛋白结晶试剂–Crystal Screen

Crystal Screen • Crystal Screen 2 • Crystal Screen HT

Applications

 Primary screen for proteins, soluble peptides, nucleic acids, & water soluble small molecules

 Sparse matrix additive screen

Features

 The original sparse matrix screen

 Sparse matrix formula efficiently samples salts, polymers, organics, & pH

 Proven effective with more than 1,000 biological macromolecules

 Tube or Deep Well block format

Description
The Crystal Screen and Crystal Screen 2 reagent kits are designed to provide a highly effective and rapid screening method for the crystallization of macromolecules. The screens are simple and practical for finding initial crystallization conditions. The initial crystallization conditions for more than 1,000 proteins, peptides, oligonucleotides, and small molecules have been determined using Crystal Screen.

A highly effective approach to overcome the exhaustive search for suitable crystallization conditions is the use of a sparse matrix method of trial conditions that is biased and selected from known crystallization conditions for macromolecules. The formulation utilized in Crystal Screen and Crystal Screen 2 evaluates 96 unique mixtures of pH, salts, polymers and organics, and their ability to promote crystal growth.

Crystal Screen contains 50 unique reagents, 10 ml each and is based on the sparse matrix formulation first described by Jancarik and Kim in 1991.

Crystal Screen 2, an extension of Crystal Screen, contains 48 unique reagents, 10 ml each and is based on the formulation first described by Cudney et al in 1994.

Crystal Screen HT contains 1 ml each of reagents 1-48 from Crystal Screen and all 48 reagents from Crystal Screen 2 in a single Deep Well block format.

Ready-to-use reagents are sterile filtered and formulated with ultra-pure Type 1 water, using the highest purity salts, polymers, organics and buffers. Individual reagents are available through the Hampton Research Custom Shop.

Crystal Screen • Crystal Screen 2 • Crystal Screen HT

Crystal Screen • Crystal Screen 2 • Crystal Screen HT

Crystals of a carbohydrate processing enzyme grown using Hampton Research Crystal Screen. Shirley Roberts, York Structural Biology Laboratory, York, United Kingdom.
Crystal Screen • Crystal Screen 2 • Crystal Screen HT

Crystal of zRFP574 red fluorescent protein grown using Hampton Research Crystal Screen 2. Pletneva et al. Acta Cryst. D62, 527-532 (2006). Nadya, Russian Academy of Science, Moscow, Russia.

CAT NO NAME DESCRIPTION
HR2-110 Crystal Screen 10 ml, tube format
HR2-112 Crystal Screen 2 10 ml, tube format
HR2-130 Crystal Screen HT 1 ml, Deep Well block format

Hampton蛋白结晶工具及仪器

Hampton蛋白结晶工具及仪器

CryoTong™ – Long
ApplicationsCrystal transfer under cryo temperature
FeaturesArtery clamp style closure30 seconds of cryo temperature180 mm length
Description
The CryoTong is a tool used to manually transfer a crystal mounted on a CrystalCap™ from liquid nitrogen to a magnetic base in a goniometer head positioned in a cryogenic stream, and then back to liquid nitrogen. The one-piece, compact CryoTong is available in two lengths. The long CryoTong is approximately 180 mm in overall length. The artery clamp style maintains the CryoTong in the closed position until the clamp is squeezed, which opens the opposing heads. The heads are non-magnetic stainless steel. The handle is magnetic stainless steel. The inside of the head is machined to closely surround the CrystalCap with loop and crystal in place. A small retaining lip is machined into the lower portion of the head to prevent the CrystalCap from slipping out of the CryoTong when the tool is in the closed position. The CryoTong can maintain the temperature of the crystal at -160°C for up to 30 seconds during room temperature crystal transfers. Choose the proper CryoTong size based upon the pin length required by the configuration of the x-ray data collection hardware used. The 18 mm CryoTong (HR5-112) is to be used with the CrystalCap HT and any other CrystalCap configured for 18 mm.HR5-114 Long CryoTong 18 mm, 180° features the head in alignment with the handle of the CryoTong.

图片

图片

图片

图片

图片

图片
Vial Clamp™ – Straight
ApplicationsVial support and manipulation
FeaturesStraight end tipHemostat style closureDescription
The Vial Clamp™ – Straight is a chrome plated, hemostat style tool. It has a tip shaped to hold the storage vial of all the CrystalCap Systems™ straight when the clamp is closed. The clamp can be locked using the hemostat style closure. This clamp makes it easy to dip the storage vial into liquid nitrogen for crystal storage. The complete length of the clamp is straight, with an overall length of 195 mm. When the vial is placed in the clamp, the length of it is positioned perpendicular, 90° to the length of the clamp.
图片
CrystalWand™ Magnetic
ApplicationsCrystalCap Magnetic & CrystalCap Copper Magnetic handling toolDescription
The CrystalWand Magnetic is designed to be used exclusively with the CrystalCap Magnetic, CrystalCap Copper Magnetic, and CrystalCap HT systems during transfer of the caps from the vial to the goniometer head and from the goniometer to the vial. The 6 1/2” (165 mm) long chrome plated steel wand features a plastic housing enclosing a spring tensioned plunger that when depressed, moves a non-magnetic steel platform away from the magnet housed in the end of the wand. This causes the steel CrystalCap to detach from the wand and be placed readily into the vial or the CryoTong™. When the platform is retracted, the wand securely holds the steel CrystalCap Magnetic. The CrystalWand Magnetic 45° (McMiken Tool) offers the same functionality but is bent at a 45° angle at approximately 2.5 cm from the magnet end.HR4-729 CrystalWand Magnetic, StraightHR4-315 CrystalWand Magnetic, 45° (McMiken Tool)

图片

图片

图片
Vial Clamp™ – Curved
ApplicationsVial support & manipulation
FeaturesCurved end tipHemostat style closureDescription
The Vial Clamp – Curved is a chrome plated, hemostat style tool. It has a tip shaped to hold the storage vial of all the CrystalCap Systems at an angle when the clamp is closed. The clamp can be locked using the hemostat style closure. The end of the clamp, where the vial is held, is curved at either a 45°/135° or 110°/ 70° angle. When the vial is placed in the clamp, the length of it is positioned to the clamp at either of those same angles. The overall length of each clamp is the same, 195 mm.HR4-671 Vial Clamp – Curved 45°/135°HR4-672 Vial Clamp – Curved 110°/70°

图片

CrystalCap™ Holder
pplicationsCrystalCap support inside stainless steel dewars
FeaturesAdjustable heightSupports up to 8 CrystalCaps15 ml vial position for liquid propane500 and 1,000 ml versionsDescription
CrystalCap Holders are convenient stands for holding all CrystalCap™ systems in liquid nitrogen dewars during crystal cryogenic procedures. Available in two sizes. Both holders feature spring-clips to secure the CrystalCap Vials in the holder. Both stands have 3 inches of adjustable Z (height) which allows one to raise or lower the CrystalCaps to the appropriate height, depending upon the liquid nitrogen level in the dewar. Each holder is supplied with a socket driver for height adjustment.500 ml version holds five CrystalCaps, two 15 ml vials (for liquid propane procedures) and fits into the 500 ml dewar. 1,000 ml version holds eight CrystalCaps, two 15 ml vials (for liquid propane procedures) and fits into the 1,000 ml dewar.HR4-707 CrystalCap Holder – 500 ml
HR4-706  Replacement Height Adjustment Tool

图片

图片

Hampton 膜蛋白结晶试剂 MembFac • Crystal Screen Lite • MembFac HT

Hampton  MembFac • Crystal Screen Lite • MembFac HT

Applications

Primary sparse matrix crystallization screen for membrane proteins and samples with limited solubility   膜蛋白和样品溶解度有限样品

Features

  Membrane protein sparse matrix screens

  Sparse matrix formula efficiently samples salts, polymers, organics and pH

  pH range 4.6 – 8.5

  Formulated for use with detergents

   Tube or Deep Well block format

   Crystal Screen Lite features a lower ionic strength than the original Crystal Screen

Description
MembFac is a highly effective sparse matrix screen specifically designed as a preliminary screen for the crystallization of membrane proteins. MembFac is based upon the highly effective biased sparse matrix methodology. The MembFac screen matrix is optimized for the crystallization of membrane proteins.

MembFac contains 48 unique reagent formulations. With this set of 48 conditions, numerous chemicals and chemical combinations are utilized, allowing one to evaluate a large variety of potential crystallization conditions. MembFac covers a broad pH range between 4 and 9.

The Rationale
The basic rationale of MembFac is to perform a sparse matrix screen while changing the detergent dimension because detergents play an important factor in the crystallization of membrane proteins. A MembFac screen is to be completed for each detergent. Detergent screens are available separately.

The Method
The membrane protein of interest is first isolated in the detergent which gives the highest stability and activity. The protein concentration should be approximately 10 to 20 mg/ml and the detergent concentration should be only slightly above the CMC. The sample is then set against MembFac, using all 48 solutions plus the screening detergent(s) of choice. The screening detergent concentration should be approximately one to three times the CMC. Hence, for each detergent screened, one would utilize approximately 1 to 2 mg of sample.

The MembFac protocol was used to crystallize membrane proteins including SQR, fumerate: quinone oxireductase, LHII, and LHCII.

Crystal Screen Lite is a sparse matrix of trial crystallization reagent conditions based upon the Crystal Screen™.3 The primary screen variables are salt, pH, and precipitant (salts, polymers, volatile organics, and non-volatile organics).2Crystal Screen Lite differs from the original Crystal Screen kit in that the primary precipitant reagents are one-half the concentration of that used in the original Crystal Screen formulation. The secondary salts, ions, and buffers remain at the original Crystal Screen concentration. Reducing the primary concentration of the primary precipitant results in a screen which is “more gentle” on the sample and typically produces much less precipitate conditions than the original Crystal Screen.

MembFac contains 48 unique reagents, 10 ml each.

MembFac HT contains 1 ml each of all 48 reagents from MembFac and reagents 1-48 from Crystal Screen Lite in a single Deep Well block format.

Ready-to-use reagents are sterile filtered and formulated with ultra-pure Type 1 water, using the highest purity salts, polymers, organics and buffers. Individual reagents are available through the Hampton Research Custom Shop.

CAT NO NAME DESCRIPTION
HR2-114 MembFac 10 ml, tube format
HR2-128 Crystal Screen Lite 10 ml, tube format
HR2-137 MembFac HT 1 ml, Deep Well block format

Hampton蛋白质结晶捞针(结晶环)18 mm Mounted CryoLoop™

Hampton蛋白质结晶捞针(结晶环)18 mm Mounted CryoLoop™

Applications

Cryocrystallography

Features

Adjustable loop orientation
Synthetic CryoLoop on adjustable stainless steel MicroTube
MicroTube specially engineered with EasySnap notches
20 micron diameter nylon CryoLoop

Description
Similar to the Mounted CryoLoop™ in design and function, the Adjustable Mounted CryoLoop allows one to manipulate and orient the CryoLoop to multiple, unique positions previously unattainable with typical cryo setups. The Adjustable Mounted CryoLoop is a 20 micron diameter synthetic loop mounted inside a malleable stainless steel sleeve, which in turn, is mounted inside the EasySnap MicroTube™.

Using a specially designed L-shaped tool (HR5-902) with a positioning notch, one can manipulate the angle and orientation of the CryoLoop by bending and adjusting the angle of the malleable stainless steel insert which holds the CryoLoop. The Adjustable Mounted CryoLoop may be positioned several times. Note: Repeated manipulation will fatigue the sleeve which can lead to failure of the sleeve. The Adjustable Mounted CryoLoop is designed to work with the CrystalCap System components.

The MicroTube is 24 mm in length and is specially engineered with EasySnap™ notches at the 10, 12, 14, 18, and 21 mm measures. To obtain the desired length of MicroTube, simply snap the MicroTube at the desired length and stake it to the CrystalCap™ Magnetic or CrystalCap™ Copper Magnetic. These nylon loops show minimal diffraction, are thin for fast freezing, strong, and aerodynamic.

Most data collection geometries prefer or require a 22 mm length between the base of the cap and the beam. For a 22 mm overall length using the CrystalCap, CrystalCap ALS, CrystalCap ALS HT and CrystalCap SPINE HT, snap the MicroTube at the second notch from the bottom, creating an 18 mm MicrozTube lenghth and secure to the CrystalCap using epoxy or similar adhesive. For a 22 mm over length using the CrystalCap Copper, CrystalCap Copper HT, CrystalCap ALS Copper HT snap the MicroTube at the fifth notch from the bottom (notch closest to the CryoLoop) and secure to the CrystalCap using epoxy or similar adhesive.

The HR5-902 Tool for Adjustable Mounted CryoLoop is not included with the Adjustable Mounted CryoLoop and must be purchased as a separated item.

18 mm Mounted CryoLoop™ - 20 micron

18 mm Mounted CryoLoop

18 mm Mounted CryoLoop™ - 20 micron

18 mm Mounted CryoLoop properly installed in a CrystalCap Magnetic

18 mm Mounted CryoLoop™ - 20 micron

Crystal in CryoLoop

CAT NO NAME DESCRIPTION
HR4-932 18 mm Mounted CryoLoop – 20 micron 0.025 – 0.05 mm – 25 pack
HR4-945 18 mm Mounted CryoLoop – 20 micron 0.05 – 0.1 mm – 25 pack
HR4-947 18 mm Mounted CryoLoop – 20 micron 0.1 – 0.2 mm – 25 pack
HR4-970 18 mm Mounted CryoLoop – 20 micron 0.2 – 0.3 mm – 25 pack
HR4-971 18 mm Mounted CryoLoop – 20 micron 0.3 – 0.4 mm – 25 pack
HR4-972 18 mm Mounted CryoLoop – 20 micron 0.4 – 0.5 mm – 25 pack
HR4-973 18 mm Mounted CryoLoop – 20 micron 0.5 – 0.7 mm – 25 pack
HR4-974 18 mm Mounted CryoLoop – 20 micron 0.7 – 1.0 mm – 25 pack
HR4-918 18 mm Mounted CryoLoop – 20 micron Sampler – 30 pack (5 of each diameter size 0.1 – 1.0 mm)

Hampton蛋白悬滴结晶板 HDP Hanging Drop Crystallization Plate

Hampton蛋白悬滴结晶板 HDP Hanging Drop Crystallization Plate

美国Hampton Research公司位于加利福尼亚州,是一家专门从事蛋白质晶体研究的生产商。该公司向全球科研人员提供全面的晶体研究试剂和相关实验耗材,同时提供晶体设计和合成方面的定制服务。Hampton Research公司以其先进的生物大分子结晶技术和广泛实用的产品线,不仅为全世界晶体研究人员的工作带来了便捷,而且也受益于科研人员的回馈不断发展自己,目前已成为晶体研究领域最受信赖的品牌之一。

Hampton research主要产品:

Crystallization Screens 用于筛选和优化蛋白质/多肽/核酸结晶的一系列经验证的高精配方型溶液

Optimize Reagents 结晶级别盐类,聚合物,有机溶液或缓冲液

Crystallization Plates, Hardware & Accessories 结晶板(悬滴法和坐滴法,微量透析,微配液,自由界面扩散,凝胶以及无容器悬浮法)及其他配件

Cryocrystallography 低温晶体学耗材如 Crystalcap system,cryoloops

Goniometer Heads&Supplies 测角器头和配件

Protein Crystallization Standards 结晶级别标准蛋白

Custom Shop Crystallization Reagents 定制试剂盒和结晶溶液内的单一组分

StockOptions Kits 内含盐类,缓冲液和冷冻液的简便型试剂盒

Tools,Seeding&Resin 结晶用探针,结晶笔,seeding法结晶工具

Capillary Mounts & Supplies 毛细管,玻璃纤维, 蜡,黏合剂和密封剂

Hampton蛋白悬滴结晶板 HDP Hanging Drop Crystallization Plate

HDP Hanging Drop Crystallization Plate (Swissci)

HDP Hanging Drop Plate

HDP Hanging Drop Crystallization Plate (Swissci)

Single Well with Tool

HDP Hanging Drop Crystallization Plate (Swissci)

Hanging Drop Wells

Applications—Hanging drop crystallization

Features

  Made from optically superior polymer (UVP)

  Allen key novel crystal plug closure system

  Wells are micro-numbered

Description  描述:
The Swissci Hanging Drop Crystallization Plate is a breakthrough for protein crystallization in a 96-well format. For the first time individual wells can be identified and removed without any disturbance to the growing crystals inside the plate.Description

The plate has been developed by Swissci AG together with leading Crystallographers. It is the result of many years of experience in successful robotic high-throughput crystallization.

The Hanging Drop Crystallization Plate offers unique properties that make it ideal for both nanoliter crystallization screening and microliter optimization alike. Made from optically superior polymer (UVP) and with a new design of the wells, the plate allows easy crystal viewing and retrieval. The system is fully covered by design and patent protection.

The Advantages of the Hanging Drop Crystallization Plate

Easy Crystal Retrieval
Raised wide wells make the crystal mounting especially easy. Allen key system allows for smooth removal and subsequent microscopic investigation / X-ray with the novel crystal plug closure all included in the system.

Easy Viewing
The wells are wide conical and have a lens effect for perfect illumination. The micro-numbering ensures you will never loose the location under the microscope.

The optically superior polymer is UV transmissible and can be used to differentiate between salt and protein crystals.

Integral Sealing
Wide partition walls between each well provides a high surface area for very good sealing with the advanced quality sealing tape. The sealing tape is integrated into the kit so there is no need to purchase additional parts prior to starting a procedure.

Wide Range of Volumes
Typical volumes are 50 – 200 µl of reservoir and 10 nanoliter – 5 microliter drop size.

SBS Standard
The complete plate is designed to the 96-well SBS standard for all common holders.

CAT NO NAME DESCRIPTION
HR3-187 Hanging Drop Crystallization Plate (Swissci) 10 plate case

Hampton蛋白悬滴结晶板 HDP Hanging Drop Crystallization Plate 相关产品:

96 Well Hanging Drop Vapor Diffusion Plate
Hanging drop crystallization
ARI Hanging Drop Seals for 96 Well Plates
ARI Hanging Drop Seals for 96 Well Plates
CrystalQuick 96 Well Sitting Drop Plate (Greiner)
Sitting drop crystallization
Detergent Screen HT
96 detergents Deep Well block format
Glass Cover Slide Gizmo Dispenser
Cover Slide Dispenser
Greiner ComboPlate and CrystalBridge
Hanging and sitting drop crystallization
HDP Hanging Drop Crystallization Plate (Swissci)
Hanging Drop Crystallization
Linbro Plate
Hanging drop crystallization
ProCrystal
Protein Crystallization Covers for Hanging Drop Vapor Diffusion
Protein Methods
Daniel M. Bollag, Michael D. Rozycki, & Stuart J. Edelstein
Solubility & Stability Screen
Identify protein specific additives that promote solubility and stability
UVP Hanging Drop Plate Seal (Swissci)
Swissci UVP Hanging Drop Plate Seal
VDX Plate with sealant
Hanging drop crystallization
VDX Plate without sealant
Hanging drop crystallization
VDX48 Plate with sealant
Hanging drop crystallization
VDXm Plate without sealant
Hanging drop crystallization
VDXm Plate with sealant
Hanging drop crystallization

 

Hampton结晶用缓冲盐试剂盒– SaltRx

Hampton结晶用缓冲盐试剂盒– SaltRx

SaltRx 1 • SaltRx 2 • SaltRx HT

Applications

Primary or secondary, salt and pH matrix crystallization screen for biological macromolecules

Features

Salt versus pH matrix crystallization screen
Samples pH 4 to 9
22 unique salts versus salt concentration and pH
Compatible with microbatch, vapor diffusion, liquid & gel diffusion methods
Tube or Deep Well block format
Preformulated, ready to screen
Developed at Hampton Research
All salts and buffers in screen readily available as Optimize™ reagents for reproducing and optimizing crystals
Individual reagents available through the Hampton Research Custom Shop
 Description
SaltRx was developed by Hampton Research as a primary and secondary, salt and pH based crystallization screen for biological macromolecules. Salt is the only primary crystallization reagent (precipitant) utilized. Based on a design of 96 conditions, the screen evaluates a broad portfolio of crystallization salts of varying concentration and pH. The selection, concentration, and pH of the salts were determined by data mining the BMCD1 and other crystallization databases, crystallization reports in the literature, and internal crystallization trials performed at Hampton Research. Based on this analysis, up to 35% of protein crystallizations involve salt as the primary crystallization reagent. SaltRx can be used as a primary crystallization screen when salt, ionic strength and pH are desired or suspected as appropriate crystallization variables. It is also useful as a secondary screen when salt only reagents/conditions from screens such as Index™, Crystal Screen™, and Grid Screen™ produce crystals and when further screening for additional salt conditions or optimization is desired. Since this screen does not contain volatile organics, it is compatible with microbatch, vapor diffusion, liquid and gel diffusion crystallization methods. SaltRx may also be used for dialysis crystallization in conjunction with Dialysis Buttons™.The original SaltRx kit (HR2-108) contained 96 unique reagents, 10 ml each. This kit has been discontinued and converted into two 48 reagent based kits, SaltRx 1 and SaltRx 2, available separately, which when used together are identical to the original SaltRx.SaltRx 1 contains 48 unique reagents, 10 ml each. SaltRx 1 contains reagents 1-48 of the original SaltRx 96 reagent kit.Salt Rx 2 contains 48 unique reagents, 10 ml each. SaltRx 2 contains reagent 49-96 of the original SaltRx 96 reagent kit.SaltRx HT contains the 96 SaltRx 1 and SaltRx 2 reagents in a single Deep Well block format.Ready-to-use reagents are sterile filtered and formulated with ultra-pure Type 1 water, using the highest purity salts, polymers, organics and buffers. Individual reagents are available through the Hampton Research Custom Shop.

Measured pH range of kit is 4.1 to 9.0 at 25°C
Average measured pH of kit is 6.9 at 25°C
Median measured pH of kit is 7.3 at 25°C
Mode measured pH of kit is 7.4 at 25°C

CAT NO NAME DESCRIPTION
HR2-136 SaltRx HT 1 ml, Deep Well block format
HR2-107 SaltRx 1 10 ml, tube format
HR2-109 SaltRx 2 10 ml, tube format

Hampton AlumaSeal™ II Sealing Film and Applicator

Hampton AlumaSeal™ II Sealing Film and Applicator

Applications

Sealing film used to reseal HT format screen kits in polypropylene blocks and plates

Features

Excellent seal
Film conforms to raised chimney wells
Easily pierceable with single or multichannel pipettors and robotic probes
Heat & cold resistant, recommended for temperatures from -80 °C to +120 °C
Certified DNase-, RNase-, and nucleic-acid-free
Less evaporation than clear films
Excellent barrier properties, virtually no reagent evaporation or drying
 Description
A 38 µm soft non-permeable aluminum foil sealing film with strong medical-grade adhesive, AlumaSeal II sealing films eliminate the need for heat-sealing devices or mats during the resealing of reagents in polypropylene deep well blocks. Each sealing film measures 82.6 x 142.9 mm and offers sufficient sealing area for 96 deep well blocks. Length between the perforations with end tabs removed is 125.4 mm. Compared to other aluminum foils, AlumaSeal II has less tendency to roll back on itself when removing the backing paper and it conforms well to the plate during application.AlumaSeal II is a soft, pierceable adhesive film designed for the convenient and rapid sealing of polypropylene deep well blocks. A multiple split backing with two end tabs allows for easy, accurate positioning and secure sealing. The use of an adhesive sealing film minimizes evaporation and helps to prevent well-to-well cross contamination in reagent blocks. AlumaSeal II films are easily pierced by pipettte tips or robotic probes or piercing tools for direct reagent recovery without significant gumming by adhesive.

AlumaSeal™ II Sealing Film and Applicator

AlumaSeal™ II Sealing Film and Applicator

CAT NO NAME DESCRIPTION
HR8-069 AlumaSeal II Sealing Film 100 pack
HR4-413 Film Sealing Paddle 5 pack

Hampton Optimize Reagents

Hampton Optimize Reagents

1、Optimize – Polymers

Crystallization grade polymers for formulating screens or optimization

2、Optimize – Organics (Volatile)

Crystallization grade organics (volatile) for formulating screens or optimization

3、Optimize – Organics (Non-Volatile)

Crystallization grade organics (non-volatile) for formulating screens or optimization

4、Optimize – Salts

Crystallization grade salts for formulating screens or optimization

5、Optimize – Buffers

Crystallization grade buffers for formulating screens or optimization

6、Optimize – Solubilizing Agents (NDSB)

Crystallization grade non detergent sulfobetaines

7、Optimize – Reducing Agent

TCEP Hydrochloride

8、Optimize – Monoolein

LCP – Lipidic Cubic Phase

9、Optimize – Cryoprotectants

For cryoprotection of crystals

10、Optimize – Oils for Crystallization

Microbatch crystallization & oil layering

11、Optimize – Izit Crystal Dye

Izit™ color dye to differentiate protein crystals from salt crystals

Hampton 水晶透明密封带Crystal Clear Sealing Tape

Hampton 水晶透明密封带Crystal Clear Sealing Tape

Crystal Clear Sealing Tape

3 inch, 1.88 inch, 1.88 inch with dispenser, 0.75 inch with dispenser (left to right)

Crystal Clear Sealing Tape

0.75 inch Crystal Clear Sealing Tape

Applications  应用
Sealing tape used to seal sitting drop crystallization experiments

Description

These optically clear tapes are compatible with protein crystallization reagents. The polypropylene Crystal Clear Sealing Tapes use acrylic solvent based adhesives which are compatible with aqueous crystallization reagents.

Catalog number HR3-511 is a 1.88 inch (48 mm) wide, 3 mil tape on a 43.7 yard (40 M) roll with a 1.5 inch core and is supplied with a green dispenser / cutter.Catalog number HR4-511 is a 1.88 inch wide, 3 mil tape on a 60 yard roll with a 3 inch core and no dispenser / cutter.Two strips of the HR3-511 or HR4-511 will seal a Corning, Cryschem, CrystalClear Strip, Greiner, Intelliplate, Linbro, Swissci (MRC), VDX and VDXm plate.Catalog number HR4-506 is a 3 inch wide, 3 mil tape on a 54.86 yard roll with a 3 inch core and no dispenser / cutter.One strip of the HR4-506 will seal a Corning, Cryschem M, CrystalClear Strip, Greiner, Intelliplate, Swissci (MRC) and VDXm plate.Crystal Clear Mini Sealing Tape HR4-508 is a 0.75 inch (19 mm) wide, 3 mil tape on a 650 inch (16.5 M) roll and is supplied with a clear dispenser / cutter. The tape is useful for resealing or patching wells after mounting crystals. The tape is also wide enough to seal a single row of a Cryschem S or Cryschem M plate.See chart for tape and plate compatibility.

Hampton GRAS 3 • GRAS 4 Screens

Hampton GRAS 3 • GRAS 4 Screens

Applications

a.GRAS reagent crystallization screen for proteins, including monoclonal antibodies, where Salt is the primary, and Polyethylene glycol the secondary reagent, sampling pH 4-9

b.Identify GRAS based reagents that promote crystallization of biotherapeutics for bioprocess, bioformulation, and continuous flow manufacturing applications

Features

Developed at Hampton Research
Generally Recognized As Safe reagent formulation
Samples pH 4.0 – 9.0 without an added buffer
Primary crystallization reagent:

24 unique Salts

 

Secondary crystallization reagent:

GRAS Screen 3: PEG 300, 400, MME 550, & 600
GRAS Screen 4: PEG 1,000, MME 2,000, 3,350 & 4,000

 

Compatible with Vapor diffusion, microbatch, free interface diffusion
Reagents soluble between 4°C and 30°C

 Description
GRAS Screen™ 3 and GRAS Screen™ 4 were developed by Hampton Research for the crystallization of proteins, including monoclonal antibodies. Each of the chemicals in GRAS Screen 3 and 4 have been used under one or more of the following categories. As (1) a Generally Recognized As Safe (GRAS) substance, (2) a pharmaceutical excipient, (3) a normal physiological constituent, (4) a metabolic byproduct, and/or (5) a Everything Added to Food in the United States (EAFUS) substance.

GRAS Screen 3 samples twenty four salts, encompassing pH 4-9 versus four low molecular weight Polyethylene glycols (300, 400, MME 550, & 600). GRAS Screen 3 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 3 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.

GRAS Screen 4 samples twenty four salts, encompassing pH 4-9 versus four medium molecular weight Polyethylene glycols (1,000, MME 2,000, 3,350 & 4,000). GRAS Screen 4 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 4 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.

 

CAT NO NAME DESCRIPTION
HR2-453 GRAS Screen 3 1 ml, Deep Well block format
HR2-454 GRAS Screen 4 1 ml, Deep Well block format

Hampton蛋白结晶小瓶和结晶柱底座CrystalCap™

Hampton蛋白结晶小瓶和结晶柱底座CrystalCap™

Applications

Cryocrystallography  低温结晶学

Features

SSRL style sample mount for cryocrystallography
CrystalCap attaches magnetically to CrystalCap Vial and Magnetic Goniometer Base
Conical shape with ledge compatible with SSRL style grippers, auto mounters and sample handlers

Description
The CrystalCap is a magnetic sample mount (also known as a cap, pin or goniometer base) designed for cryocrystallography systems that accept SSRL style sample mounts. The CrystalCap attaches to a magnetic CrystalCap Vial and Magnetic Goniometer Base. The tip of the CrystalCap accepts a Mounted CryoLoop™ or MicroTube™ fitted with a CryoLoop™.

The CrystalCap Vial is a 1.8 ml cryo vial featuring two small vents. A ring magnet is molded into the open end of the vial so that when the cap is positioned in the vial, the ring magnet holds the cap on the vial during cryogenic storage.The HR4-904 CrystalCap Vial does not have a magnet on the bottom of the vial.

The conical shape with ledge is compatible with SSRL style grippers, auto mounters and sample handlers.

Compatible with the following Synchrotron Radiation Beamlines

North & South America
• The Advanced Light Source, Berkeley, California ALS 4.2.2, ALS 11.3.1, ALS 12.2.2, ALS 12.3.2
• The Advanced Photon Source, Argonne, Illinois APS 14-BM-C BioCARS, APS 14-ID-B BioCARS
• Cornell High Energy, Synchrotron Source, Ithaca, New York CHESS A1, CHESS F1
• Canadian Light Source, Saskatchewan, Canada, CLS 08ID-1, CLS 08B1-1
• National Synchrotron Light Source, Upton, New York NSLS X4C
• Stanford Synchrotron Radiation Laboratory, Menlo Park, California SSRL BL7-1, SSRL BL9-1, SSRL BL9-2, SSRL BL11-1, SSRL BL12-2, SSRL BL14-1

Asia & Australia
• Shanghai Synchrotron Radiation Facility, Shanghai, China SSRF BL17U1
• National Synchrotron Radiation Research Center, Taiwan NSRRC BL13B1, NSRRC BL13C1
• Pohang Accelerator Laboratory, Pohang, South Korea PAL 2D, PAL 5C, PAL 7A
• Photon Factory, Tsukuba, Japan PF BL-5A, PF BL-17A, PF AR-NW12A
• Super Photon ring-8 GeV, Japan SPRING-8 BL12B2, SPRING-8 BL24XU, SPRING-8 BL26B1, SPRING-8 BL26B2, SPRING-8 BL32B2, SPRING-8 BL32XU, SPRING-8 BL38B1, SPRING-8 BL41XU, SPRING-8 BL44B2, SPRING-8 BL44XU

CrystalCap™

CrystalCap

CrystalCap™

CrystalCap & Vial

CrystalCap™

CrystalCap

Hampton蛋白结晶小瓶和结晶柱底座 CrystalCap™

CAT NO NAME DESCRIPTION
HR4-733 CrystalCap with Vial – 60 pack
HR4-902 CrystalCap without Vial – 60 pack
HR4-904 CrystalCap Vial Vial only – 30 pack

Hampton 蛋白结晶优化试剂 Optimization Screens

Hampton 蛋白结晶优化试剂 Optimization Screens

1、Solubility & Stability Screen  蛋白特异性试剂优化溶解性和稳定性

Protein specific agents for optimization of solubility & stability  

2、Solubility & Stability Screen 2   离子缓冲液

Buffer, pH & ionic strength screen for optimization of solubility & stability

3、Slice pH    PH缓冲液

pH & buffer screen for optimization of crystals or sample solubility & stability

4、Additive Screen  96孔板添加剂试剂盒

96 compound screen for optimization of crystal size & quality

5、Silver Bullets • Silver Bullets Bio

Small molecule additive screen for optimization of crystal size & quality

6、Detergent Screen

Detergent screen for optimization of crystals or sample solubility & stability

7、Ionic Liquid Screen

Ionic liquid additive screen for optimization of crystal size & quality

8、StockOptions Buffer Kits

Titrated buffer sets for optimization of crystals or sample solubility & stability

9、StockOptions Polymer

n of crystal size & quality

10、StockOptions Salt

Salt reagent kit for optimization of crystal size & qualit

11、Polymer reagent kit for optimizatioy

Proti-Ace

In situ proteolysis kit protein for crystallization screening & optimization

12、Reductive Alkylation

Reductive alkylation kit for crystallization screening & optimization

13、Silica Hydrogel Kit

pH neutral silica hydrogel matrix crystallization

14、Low Melting Agarose

Agarose gel matrix crystallization

15、CryoPro

Water soluble cryoprotectant reagent set

16、Heavy Atom Screens

Heavy atom kits for multiple isomorphous replacement

17、I3C Phasing Kit

Produce heavy atom derivative of biological macromolecules for phasing

Hampton蛋白结晶产品目录

Hampton蛋白结晶产品目录

产品编号 中文品名 英文品名
HR4-126 11 刀片替换装 Replacement #11 Blade
HR4-904 CrystalCap Magnetic Vial CrystalCap™, Vial only
HR4-729 CrystalWand Magnetic, Straight CrystalWand™ Magnetic, Straigh
HR4-837 Micro-Tools II Set Micro-Tools II™ Set
HR4-811 Micro-Tools Set Micro-Tools™ Set
HR3-172 VDX 24孔板,带密封剂 VDX™ Plate, with sealant
HR4-902 带磁力底座 CrystalCap™, without Vial
HR4-733 带磁力底座 CrystalCap™, with Vial
HR4-745 带铜管磁力底座 CrystalCap™ Copper 18 mm, with
HR4-708 冻存套 CryoSleeve™
HR3-217 硅化方形盖玻片22mmx0.22mm 22 mm x 0.22 mm Siliconized Sq
HR4-671 夹钳-弯 Vial Clamp™ – Curved, 45°/135°
HR4-670 夹钳-直 Vial Clamp™ – Straight
HR4-316 Super Glue
HR4-506 胶带 3 inch wide x 55 yard Crystal
HR3-083 结晶板 2孔 MRC 2 Well Crystallization Pla
HR3-125 结晶板 3孔 3 Well Crystallization Plate (
HR4-217 晶体探针 Crystal Probe
HR4-662 泡沫保温瓶 Spearlab Cryogenic Foam Dewar
HR4-673 泡沫保温瓶 Spearlab Cryogenic Foam Dewar
HR4-674 泡沫保温瓶 Spearlab Cryogenic Foam Dewar
HR4-675 泡沫保温瓶 Spearlab Cryogenic Foam Dewar
HR1-008 液氮罐 CX100 (含运输箱) CX100 Cryo-Express Dry Shipper
HR2-912-37   Crystal Screen 2™ #37
HR2-501   50% v/v Jeffamine® M-600® pH 7
HR2-509   1.0 M BICINE
HR2-517   100% Polyethylene glycol 300
HR2-523   50% w/v Polyethylene glycol 1,
HR2-525   50% w/v Polyethylene glycol 1,
HR2-529   50% w/v Polyethylene glycol 4,
HR2-533   50% w/v Polyethylene glycol 6,
HR2-537   1.0 M Magnesium formate dihydr
HR2-541   3.5 M Ammonium sulfate
HR2-545   2.0 M Lithium sulfate monohydr
HR2-547   7.0 M Sodium formate
HR2-549   1.6 M Sodium citrate tribasic
HR2-551   4.0 M Sodium phosphate monobas
HR2-557   2.0 M Calcium chloride dihydra
HR2-563   1.0 M Zinc acetate dihydrate
HR2-102   StockOptions™ Hepes
HR2-103   StockOptions™ Bis-Tris Propane
HR2-104   StockOptions™ Citric Acid
HR2-106   StockOptions™ Bis-Tris
HR2-107   SaltRx™ 1
HR2-109   SaltRx™ 2
HR2-110   Crystal Screen™
HR2-112   Crystal Screen 2™
HR2-114   MembFac™
HR2-116   Natrix™
HR2-117   Natrix™ 2
HR2-118   Nucleic Acid Mini Screen™
HR2-126   PEG/Ion Screen™
HR2-235   StockOptions™ Sodium Citrate
HR2-237   StockOptions™ Tris Hydrochlori
HR2-239   StockOptions™ Sodium Cacodylat
HR2-241   StockOptions™ pH
HR2-245   StockOptions™ Salt
HR2-249   StockOptions™ Succinic Acid
HR2-320   Seed Bead™
HR2-406   Detergent Screen HT™
HR2-428   Additive Screen™
HR2-434   Reductive Alylation Kit
HR2-442   Heavy Atom Screen™ Pt
HR2-444   Heavy Atom Screen™ Au
HR2-446   Heavy Atom Screen™ Hg
HR2-448   Heavy Atom Screen M1™
HR2-450   Heavy Atom Screen M2™
HR2-082   PEGRx™ 1
HR2-084   PEGRx™ 2
HR2-096   Silver Bullets™
HR2-098   PEG/Ion 2 Screen™
HR4-315   CrystalWand™ Magnetic, 45° McM
HR4-350   Large Applicator (200 & 350 µl
HR4-625   Mounted CryoLoop™ – 20 micron,
HR4-637   CryoTong™ 18 mm (standard 110
HR4-709   CryoCane™ 5 Vial Holder
HR4-711   CryoCane™ 6 Vial Holder
HR2-211   Grid Screen™ Ammonium Sulfate
HR2-213   Grid Screen™ PEG 6000
HR2-227   StockOptions™ Polymer
HR2-233   StockOptions™ Sodium Acetate
HR4-931   CryoLoop™ – 20 micron, 0.2 – 0
HR4-945   Mounted CryoLoop™ – 20 micron,
HR4-947   Mounted CryoLoop™ – 20 micron,
HR4-953   Mounted CryoLoop™ Sampler – 20
HR4-955   Mounted CryoLoop™ – 20 micron,
HR4-957   Mounted CryoLoop™ – 20 micron,
HR4-959   Mounted CryoLoop™ – 20 micron,
HR4-961   Mounted CryoLoop™ – 20 micron,
HR4-963   Mounted CryoLoop™ – 20 micron,
HR4-970   Mounted CryoLoop™ – 20 micron,
HR4-971   Mounted CryoLoop™ – 20 micron,
HR4-989   CryoLoop™ – 10 micron, 0.3 – 0
HR2-128   Crystal Screen Lite™
HR2-138   Additive Screen HT™
HR2-140   PCT™ – Pre-Crystallization T
HR4-313   Mounted CryoLoop™ – 20 micron,
HR2-601   100% Polyethylene glycol 200
HR2-607   50% w/v Polyethylene glycol 10
HR2-609   30% w/v Polyethylene glycol 20
HR2-611   100% Polyethylene glycol monom
HR2-613   50% w/v Polyethylene glycol mo
HR2-615   50% w/v Polyethylene glycol mo
HR2-625   6.0 M 1,6-Hexanediol
HR2-637   5.0 M Sodium chloride
HR2-723   1.0 M BICINE pH 9.0
HR2-755   100% Tacsimate™ pH 7.0
HR2-761   3.0 M DL-Malic acid pH 7.0
HR2-801   TCEP hydrochloride
HR2-821   2.0 M Magnesium sulfate heptah
HR2-829   100% Tacsimate™ pH 8.0
HR2-857   4.0 M TMAO
HR2-859   100% Polyethylene glycol 600
HR2-910-08   Crystal Screen™ #08
HR2-144   Index™
HR4-993   Mounted CryoLoop™ Sampler – 10
HR4-995   Mounted CryoLoop™ – 10 micron,
HR4-999   Mounted CryoLoop™ – 10 micron,
HR6-146   1.0 mm Quartz Capillary
HR8-034   Cryo Puck Carrier
HR8-035   Porcupine Push Tool
HR8-036   Puck Wand
HR8-037   Cryo Puck Base Removal Platfor
HR8-038   Angled Cryo Puck Tong
HR8-039   Cryo Puck Dewar Loading Tool
HR8-114   CrystalCap HT™, Vial only
HR8-133   Seeding Tool
HR8-173   CrystalCap™ Copper HT, 0.025 –
HR8-174   CrystalCap™ Copper HT, 0.05 –
HR8-175   CrystalCap™ Copper HT, 0.1 – 0
HR8-176   CrystalCap™ Copper HT, 0.2 – 0
HR2-575   1.0 M Sodium cacodylate trihyd
HR2-581   1.0 M Hydrochloric acid

Hampton Solubility & Stability Screen

Hampton Solubility & Stability Screen

Solubility & Stability Screen(溶解度和稳定性的屏幕)
应用:溶解性和稳定性屏幕的设计,以协助识别解决方案的条件,促进蛋白质的溶解性和稳定性,并尽量减少蛋白质沉淀。
Solubility & Stability Screen
Solubility & Stability Screen
Solubility & Stability Screen
Solubility & Stability Screen HR2-072
Applications

A solubility screen, a stability screen, an additive screen for protein assays including ThermoFluor and crystallization
Preformulation screening

 

Compatible with Thermofluor , Differential Scanning Fluorimetry (DSF), and Protein Thermal Shift assays
96 sterile filtered reagents
17 classes of reagents and excipients
Highly concentrated (10x) reagent formulation
Developed at Hampton Research

Features
Methodologies

Thermal shift assay
Dynamic Light Scattering
Use Solubility & Stability Screen along side Slice pH and Solubility & Stability Screen 2 to optimize sample buffer
Description

Solubility & Stability Screen is designed to assist in the identification of solution conditions which promote protein solubility and stability, and minimize protein precipitation. Solubility & Stability Screen is a solubility screen, a stability screen, and may also be used as an additive screen in the presence of a crystallization reagent.
The Hampton Research Solubility and Stability Screen can evaluate protein solubility, stability and crystallization in the presence of 94 different chemical additives sampling 17 different classes of reagents plus two controls.
Protein solubility and stability are universally required in a wide range of applications, including general biochemical studies, the preparation of proteins in pharmaceuticals, structural biology and crystallization.1-11The preparation of a concentrated, soluble and stable protein sample can often be a difficult task as proteins often aggregate, precipitate or denature.
Thermofluor (also known as Differential Scanning Fluorimetry, DSF and Protein Thermal Shift) provides a rapid, convenient and effective means of identifying subsaturating solution conditions that may also correlate with protein heterogeneity and poor crystallization outcomes.12
Protein solubility and stability is affected by many different chemical factors including pH, buffer type, chemical additives and excipients. pH and buffer type are dominant protein solubility and stability variables and can be evaluated and optimized using the Hampton Research Slice pH kit HR2-070. Slice pH evaluates protein solubility, stability and crystallization versus 20 different buffers over the pH range 3.5-9.6. Chemical additives influencing protein solubility and stability can be evaluated using the Solubility & Stability Screen.
It is widely accepted that protein solubility and stability can be increased by the use of chemical additives.5,15Seventeen classes of reagents are sampled by the Solubility & Stability Screen and each of these classes has been reported as important in improving sample solubility and stability.2-11
The Solubility & Stability Screen is a set of 94 high purity reagents formulated in high purity water (NCCLS/ASTM Type 1+) at 25°C and are 0.22 micron sterile filtered. The 94 solubility and stability reagents are formulated at 2 to 10 times their recommended working concentration. The remaining two reagents are water and a negative (TCA) control. A water control demonstrates the effect of diluting sample as well as sample buffer concentration. TCA, the negative control, demonstrates total sample precipitation, loss of sample solubility and loss of sample stability. The effects of the Solubility & Stability reagents can be compared with this negative control to assist in the identification of reagents promoting sample solubility and stability. 500 microliters of each reagent is supplied in a sterile 96 well polypropylene Deep Well block. The Solubility & Stability Screen reagents are compatible with the sitting or hanging drop vapor diffusion, microbatch, free interface diffusion, sandwich drop vapor diffusion, and dialysis crystallization methods utilizing water soluble reagents.